JMB Safe Portable Lighting Transformer 220V/380V to 12V/24V/36V
On a mine face, inside a ship hull, or in a tunnel with water running down the walls, mains voltage and portable hand lamps are a…
- Factory-direct pricing, no middleman markup
- Custom voltage, capacity and branding (OEM)
- MOQ from 10 pcs, production 15–25 days
- 12-month warranty with reliable support
On a mine face, inside a ship hull, or in a tunnel with water running down the walls, mains voltage and portable hand lamps are a dangerous combination. The JMB safe portable lighting transformer exists to remove that risk: it takes 220V or 380V mains and steps it down to a safety extra-low voltage of 12V, 24V or 36V, so the lamp a worker is holding cannot deliver a lethal shock even if the cable is damaged and the fitting is standing in water. The secondary winding is galvanically isolated from the mains, which means the output has no reference to earth at all. We build the JMB range in Yueqing with cold-rolled oriented silicon steel cores and oxygen-free copper windings, in enclosures built for rough handling, and we supply them with the explosion-proof and waterproof lamp heads that site work actually requires.
Key Specifications
| Specification | Value |
|---|---|
| Models | JMB-25 / JMB-50 / JMB-100 / JMB-150 / JMB-250 / JMB-300 / JMB-500 and above |
| Capacity Range | 25VA to 5000VA |
| Input Voltage | 220V or 380V AC (dual primary available) |
| Output Voltage | 12V / 24V / 36V AC safety extra-low voltage |
| Frequency | 50Hz / 60Hz |
| Isolation | Galvanic isolation between primary and secondary, output floating |
| Core | Cold-rolled grain-oriented silicon steel, high permeability |
| Winding | T1 grade high-purity oxygen-free copper wire |
| Enclosure | Portable steel case with carry handle, optional waterproof or explosion-proof |
| Ambient Temperature | -25 degrees C to +40 degrees C |
| Relative Humidity | Up to 90% |
| Protection | Thermal cut-out, earth screen between windings |
| Warranty | 12 months, replacement-first |
What You Get
- JMB safety isolation transformer wound to your specified input and output voltages
- Galvanically isolated secondary – the output is floating and safe to touch
- Oxygen-free copper windings on a cold-rolled oriented silicon steel core
- Portable steel enclosure with carry handle, built for site conditions
- Thermal cut-out and earthed screen between primary and secondary
- Terminals clearly marked, wiring diagram fixed to the case
- 12-month replacement-first warranty
Why Choose This Model
The safety case for a JMB lighting transformer is simple and worth spelling out. A shock becomes lethal because current flows through the body to earth. On a 220V supply in a wet tunnel, a damaged lamp cable can easily deliver that current. On the isolated 12V, 24V or 36V secondary of a JMB transformer, there is no path to earth at all, because the secondary winding has no electrical connection to the mains or to ground. A worker can touch a live conductor and feel nothing. That is why safety rules in mining, tunnelling, shipbuilding and confined-space work call for safety extra-low voltage on portable lamps, and why inspectors look for the transformer before they look at anything else. Beyond safety, the practical case matters too: the JMB is built to be carried, dropped and used in the rain. The core is cold-rolled oriented silicon steel for low loss and low heat, the windings are T1 grade oxygen-free copper so they run cool and resist oxidation, and the case is steel with a handle rather than a plastic box that cracks the first time it is knocked off a scaffold. We build these for contractors working in African mines, Southeast Asian construction sites and Middle Eastern oilfield maintenance, where the equipment has to survive conditions that would finish a consumer-grade unit in a week.
How to Size It
Size the transformer on the total wattage of the lamps it will run at the same time, then add roughly 20 percent headroom so the unit is not sitting at its limit all shift. A single 100W portable lamp on a 36V circuit needs a transformer rated at about 120VA or larger; four of them need 500VA. Cable length matters more than people expect: at 12V the current is high and voltage drop over a long run is significant, so if the lamp is more than about 20 metres from the transformer, either move the transformer closer or specify 24V or 36V instead of 12V to halve or third the current. Tell us the lamp wattage, the number of lamps and the cable run, and we will specify the right rating and output voltage for the job.
How It Works
The protection a JMB provides comes from galvanic isolation, not from the voltage reduction alone, and the difference matters. A transformer transfers energy through a magnetic field: the primary winding and the secondary winding are physically separate coils with no electrical connection between them. So the 12V, 24V or 36V secondary circuit has no reference to the mains and no reference to earth. Touch one conductor and no current flows, because there is nowhere for it to flow to. Touch both conductors and you still only have 12V, 24V or 36V across you. This is why safety extra-low voltage circuits are specified for portable hand lamps in conductive locations, and why the rules require the transformer to be a genuine safety isolating transformer rather than an autotransformer or a switched-mode supply. An autotransformer shares a winding between input and output, so the output is still referenced to mains and provides no protection at all. We build the JMB with a true double-wound isolating construction, plus an earthed screen between the windings so that a primary-to-secondary insulation fault shows up as an earth fault rather than putting mains on the lamp lead.
Typical Applications
- Underground mining and tunnel boring
- Confined-space work in tanks, boilers and pressure vessels
- Shipbuilding, ship repair and hull inspection
- Oil and gas maintenance in hazardous areas
- Construction sites and temporary site lighting
- Maintenance work in wet or conductive locations
- Any application where portable hand lamps run near earthed metal
Testing Before Shipment
Each JMB is tested before it leaves the bench. We verify the turns ratio, measure the output voltage on load to confirm regulation, and check the insulation resistance both between windings and from each winding to the core and frame – the latter being the test that matters most for a safety transformer, since it is what guarantees the secondary is genuinely floating. We confirm the earthed screen is continuous and correctly bonded, check that the thermal cut-out operates, and run the unit at rated load until the temperature stabilises. Each order ships with a test report covering these results. If your project requires third-party certification, dielectric testing to a specific standard, or particular documentation for a mine safety inspector or a site approval, tell us when you enquire so we can confirm exactly what we can supply before you commit.
Ordering, Samples and Shipping
The JMB range is made to order with a 10 pcs minimum and a 15-25 day lead time, and we need four things to quote: the input voltage (220V or 380V), the output voltage (12V, 24V or 36V), the capacity in VA, and the quantity. If you need a particular enclosure – waterproof, explosion-proof, or a specific ingress rating – tell us at the same time, because it changes both the build and the lead time. We can also supply the matching portable lamp fittings if you want the transformer and the lamps as one line item. Samples are available and are paid by T/T before production, with the sample cost credited against a subsequent production order. Standard shipping is FOB Ningbo or Shanghai, and sample quantities can go by air courier.
Jmb safe portable lighting transformers, wound and 100% tested in Yueqing, China. MOQ 10 pcs, lead time 15-25 days, FOB Ningbo or Shanghai.
More from This Range
JMB Lighting Control TransformerFixed-installation lighting control
BK Control TransformerMachine control power
JBK Machine Control TransformerTerminal-board type for machine tools
FAQ
What does a safe portable lighting transformer do?
It steps 220V or 380V mains down to a safety extra-low voltage of 12V, 24V or 36V, and isolates the output from the mains entirely. Because the secondary is floating with no path to earth, a worker can touch a live conductor on the lamp circuit without receiving a dangerous shock.
Is 12V, 24V or 36V the right output?
All three are safety extra-low voltages. 12V is the most conservative and is common in very wet or confined locations, but it draws the highest current, so voltage drop over long cable runs is a problem. 24V and 36V allow longer runs and smaller cable. We will advise based on your lamp wattage and distance.
Can it be used with explosion-proof or waterproof lamp heads?
Yes. The JMB is designed to be paired with explosion-proof or waterproof portable lamp fittings, which is how it is used in mining, tunnelling and hazardous-area maintenance work. Tell us the fitting type and we will match the output rating.
What is the enclosure like?
A portable steel case with a carry handle, built for site handling. Waterproof and explosion-proof enclosure options are available for hazardous locations.
What are the MOQ, lead time and warranty?
MOQ is 10 pcs with a lead time of 15-25 days. Every unit carries a 12-month replacement-first warranty. Shipping is FOB Ningbo or Shanghai.